● Centrifugal Fan vs Axial Fan: Key Differences
● Airflow Direction: How Each Fan Moves Air
>> Axial Fan Airflow: Straight Through the Impeller
>> Centrifugal Fan Airflow: A Radial Turn
● Static Pressure Comparison: Which Fan Handles Resistance Better?
>> Why Maximum Airflow Can Be Misleading
● An Illustrative Comparison: Same Airflow, Different Pressure Needs
● Noise, Efficiency, and AC vs DC Operation
● A Five-Step Fan Selection Workflow
>> 1. Establish the Thermal Requirement
>> 2. Map the Complete Air Path
>> 3. Determine System Resistance
>> 4. Compare Complete Fan Curves
>> 5. Validate Real Operating Conditions
● Industry Lesson: Enclosure Changes Can Change the Best Fan
● Discuss Your Duty Point with Capital Technology
>> 1. What is the main difference between centrifugal and axial fans?
>> 2. Do centrifugal fans always produce higher pressure?
>> 3. Can I replace an axial fan with a centrifugal fan?
>> 4. Which fan is better for filtered equipment?
>> 5. Does higher maximum airflow guarantee better cooling?
The centrifugal fan vs axial fan decision starts with two questions: where must the air travel, and how much resistance must it overcome? An axial fan moves air parallel to its shaft. A centrifugal fan draws air in axially and redirects it radially outward, approximately 90 degrees from the inlet direction.
For equipment designers, this difference affects enclosure layout, cooling performance, noise, and power consumption. Our selection principle is straightforward: compare operating airflow, not just maximum airflow.
At Capital Technology Co., Limited, our cooling portfolio includes CAPITAL-branded DC and AC fans alongside SANYO DENKI products. This guide explains how to evaluate both fan types without relying on oversimplified "more airflow" or "more pressure" claims.

| Comparison | Axial fan | Centrifugal fan |
|---|---|---|
| Airflow direction | Primarily parallel to the shaft | Axial inlet; radial discharge |
| Typical strength | High airflow through relatively open paths | Air movement through restrictive paths |
| Pressure capability | Model-dependent; specialized designs achieve high pressure | Often suitable for higher-resistance systems |
| Installation | Fits straight-through ventilation layouts | Requires radial discharge clearance or a suitable housing |
| Common applications | Electronics, cabinets, servers, ventilation | Filtered equipment, heat exchangers, compact ducted systems |
| Selection priority | Stable airflow at the required pressure | Pressure capability and discharge-path compatibility |
These are general tendencies, not universal rankings. Fan diameter, speed, impeller design, and installation conditions can change the comparison considerably.
An axial fan draws air through its inlet and discharges it along the rotating shaft's axis. This makes it convenient for panel mounting and straight-through equipment ventilation.
However, straight-through discharge does not guarantee that air reaches every hot component. Internal obstructions, bypass paths, and recirculation can undermine an otherwise suitable fan.
A centrifugal impeller draws air toward its center and accelerates it outward. An unhoused impeller discharges around its circumference; a scroll housing collects that flow and directs it toward an outlet.
This distinction matters when comparing centrifugal fans and blowers. Not every centrifugal fan has a single side outlet. Installation space must accommodate the actual discharge arrangement.
The direction change can suit shallow enclosures, but insufficient inlet clearance or obstructed radial discharge can restrict performance.
Static pressure is an important selection measure when air must pass through filters, heat sinks, grilles, or densely packed components.
Conventional axial fans often suit lower-resistance paths. Centrifugal designs frequently offer useful performance where resistance is higher. However, high-static-pressure axial fans—including counter-rotating designs—can also serve demanding cooling applications.
Avoid selecting by fan category alone.
Catalog maximum airflow is measured at zero static pressure. Maximum static pressure occurs at zero airflow. These are opposite endpoints, not simultaneous operating conditions.
The actual operating point occurs where the fan curve intersects the system-resistance curve.
A fan advertising greater free-air delivery may therefore move less air inside your equipment than a lower-rated model with better pressure capability.
Also compare like-for-like pressure data. Fan static pressure and fan total pressure are different quantities.

Consider two hypothetical enclosures:
| Design condition | Open enclosure | Restrictive enclosure |
|---|---|---|
| Required airflow | 100 m³/h | 100 m³/h |
| Estimated pressure requirement | 30 Pa | 180 Pa |
| Initial candidates | Conventional axial fans | Centrifugal or high-pressure axial fans |
These values illustrate a selection method; they are not measured product results.
Both enclosures require identical airflow, but the second needs substantially more pressure at that airflow. A maximum-airflow specification above 100 m³/h does not prove suitability for either enclosure.
Request performance curves and identify candidates that deliver the required duty point within their recommended operating range. Then test them in the assembled equipment.

Neither design is automatically quieter.
Noise depends on rotational speed, operating point, turbulence, blade geometry, and installation. An axial fan operating near a stall region can experience unstable airflow and increased noise. A centrifugal fan can also perform poorly when its inlet or discharge is obstructed.
Compare acoustic data under equivalent measurement conditions and at the required duty point—not simply at maximum speed.
Compare electrical input while delivering the same useful airflow against the same pressure requirement.
Speed control can reduce unnecessary operation, but confirm each model's control interface. PWM availability, feedback signals, and allowable speed ranges vary.
AC and DC describe electrical supply arrangements; axial and centrifugal describe airflow geometry. An axial fan is not necessarily AC, and a centrifugal fan is not necessarily DC.
Estimate the heat that ventilation must remove and the allowable air-temperature rise.
A useful starting relationship is:
Q=P/ρcpΔT
Here, Q is airflow in m³/s, P is heat transferred to the air in watts, ρ is air density, and cp is specific heat capacity.
This estimates bulk ventilation needs, not individual component temperatures.
Include inlet grilles, filters, heat sinks, cable bundles, outlets, and internal turns. Identify possible bypass and recirculation paths.
Measure resistance where practical. Otherwise, begin with an engineering estimate and validate it experimentally.
For many predominantly turbulent systems, pressure loss rises approximately with airflow squared. Filters and other elements can require a more detailed model.
Check airflow, pressure, electrical input, acoustics, dimensions, environmental ratings, and control requirements. Avoid unstable or manufacturer-restricted operating regions.
Test at relevant ambient temperatures, supply conditions, and equipment loads. Include anticipated filter loading where applicable.
Successful selection means acceptable component temperatures—not merely detectable exhaust airflow.

A published SANYO DENKI case describes lighting equipment whose existing axial-fan cooling became insufficient after the equipment was made thinner.
The proposed alternative was a splash-proof centrifugal fan. Its redirected airflow and high-pressure characteristics addressed the revised installation constraints.
This is a supplier-published application example, not a Capital Technology project or a universal comparison. Its practical lesson is valuable: changing enclosure geometry can justify reconsidering the fan type, even when the original design previously worked.
Send Capital Technology your target airflow and pressure, enclosure drawing, heat load, supply voltage, ambient conditions, noise limit, and expected annual quantity.
Ask us to compare suitable CAPITAL and SANYO DENKI options against your required duty point, with supporting performance curves and sample-validation requirements.
Axial fans move air along the shaft axis. Centrifugal fans draw air in axially and discharge it radially.
No. Specialized axial designs can generate high static pressure. Compare individual performance curves.
Possibly, but discharge direction, clearances, mounting, wiring, and system performance require reassessment.
Select the model that delivers sufficient airflow against the filter and enclosure resistance, including anticipated loading.
No. Installed airflow, air distribution, and component temperatures determine whether cooling is adequate.
1. SANYO DENKI. "Types of Fans." Explains airflow mechanisms, fan categories, and counter-rotating axial designs. [techcompass.sanyodenki]
2. SANYO DENKI. "Centrifugal Fan Structure." Describes radial discharge, inlet arrangements, and operating characteristics. [techcompass.sanyodenki]
3. SANYO DENKI. "Fan Airflow and Static Pressure." Explains performance-curve endpoints and installed operating points. [techcompass.sanyodenki]
4. Air Movement and Control Association International. "Fan and System Curves with Fan Energy Index (FEI), Part 1 of 2." Explains system resistance and duty-point selection. [amca],-part-1-of-2.pdf)
5. SANYO DENKI. "Fan Basics and Selection Criteria (How to Use)." Technical report covering fan types, high-pressure axial designs, and thermal airflow calculations. [sanyodenki]
6. SANYO DENKI. "What Is an Axial Fan? Features, Structure and Usage." Discusses axial-fan construction and rotating stall. [techcompass.sanyodenki]
7. SANYO DENKI. "High Static Pressure 'Splash Proof Centrifugal Fan' Makes Outdoor Installation Possible." Supplier-published lighting-equipment application example. [techcompass.sanyodenki]